Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

IntroductionEndovascular repair of aortic aneurysms with difficult anatomy is challenging. There is no consensus for planning such procedures.MethodsSix cases of aortic aneurysms with challenging anatomical features, such as short, angulated, and conical necks and tortuous iliacs were harvested. The computed tomography (CT) scans were anonymized. Lifesize 3-dimensional (3-D) printed models were created of the lumen. Endovascular operators were asked to review the CT angiography (CTA), make a management plan, and give an indication of their confidence. They were then presented with the equivalent model and asked to review their decision. Their attitudes to such models were briefly surveyed.ResultsA total of 28 endovascular operators reviewed 144 cases. After review of the physical model, the management plan changed in 29 (20.1%) of 144 cases. Initial plan after CTA review was endovascular 73.6%, open repair 22.9%, and second opinion 3.5%. After model review, this became endovascular 67.4%, open repair 19.4%, and second opinion 4.8%. Although the general trend was toward more open procedures, off-label techniques reduced from 19.4% to 15.2% following model review. When the management plan did not change, level of confidence did increase in 37 (43.5%) of 85 cases. The majority of operators stated that they would find models useful for planning in some procedures. For 1 case, the change in the percentage of participants being sure in the management plan was statistically significant (P = .031).ConclusionThe 3-D printed models may be potentially useful in planning cases with EVAR. It is a paradigm that warrants further investigation.

Original publication

DOI

10.1177/1538574415623651

Type

Journal article

Journal

Vascular and endovascular surgery

Publication Date

01/2016

Volume

50

Pages

4 - 9

Addresses

Department of Radiology, Southend University Hopsital NHS Foundation Trust, Southend, United Kingdom matthewtam2005@gmail.com.

Keywords

Humans, Aortic Aneurysm, Abdominal, Radiographic Image Interpretation, Computer-Assisted, Aortography, Blood Vessel Prosthesis Implantation, Pilot Projects, Predictive Value of Tests, Blood Vessel Prosthesis, Patient Selection, Models, Anatomic, Endovascular Procedures, Printing, Three-Dimensional, Computed Tomography Angiography