We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

We assessed the efficacy of intraoperative frozen-section histology in detecting infection in failed arthroplasties in 106 hips and knees. We found inflammatory changes consistent with infection (an average of one or more neutrophil polymorphs or plasma cells per high-power field in several samples) in 18 cases; there was a significant growth on bacterial culture in 20 cases. Compared with the bacterial cultures, the frozen sections provided two false-negative results and three false-positive results (sensitivity, 90%; specificity, 96%; and accuracy, 95%). The positive predictive value was 88%, the negative value, 98%. These results support the inclusion of intra-operative frozen-section histology in any protocol for revision arthroplasty for loose components.

Original publication

DOI

10.1302/0301-620x.77b1.7822391

Type

Journal article

Journal

The Journal of Bone and Joint Surgery. British volume

Publisher

British Editorial Society of Bone & Joint Surgery

Publication Date

01/1995

Volume

77-B

Pages

28 - 33